45 research outputs found

    Integrated simulation of ground motion mitigation, techniques for the future compact linear collider (CLIC)

    Get PDF
    CLIC is a proposal of CERN for a future high-energy particle collider. CLIC will collide electron and positron beams at a centre of mass energy of 3TeV with a desired peak luminosity of 2x10^3^4cm^-^2s^-^1. The luminosity performance of CLIC is sensitive to ground motion. Ground motion misaligns accelerator components, most importantly quadrupole magnets, which leads to emittance growth and beam-beam offset at the interaction point. This paper discusses the beam based feedback strategies currently used together with mechanical stabilization systems to address the above mentioned issues. These strategies consist of an Interaction Point Feedback (IPFB) and an Orbit Feedback (OFB). The two feedbacks have been designed independently and the main objective of this paper is to show how they interact. A simulation program is used in order to simulate the whole collider, it includes the behaviour of the beams, magnets, supports, ground attenuators, sensors, and actuators. Beam-offset feedback optimization and integrated simulations have been performed and results show that despite a detrimental coupling of both feedbacks at high frequency, it is possible to decrease the beam-beam offset and maintain the desired luminosity

    BDS tuning and Luminosity Monitoring in CLIC

    Full text link
    The emittance preservation in the Beam Delivery System (BDS) is one of the major challenges in CLIC. The fast detuning of the final focus optics requires an on-line tuning procedure in order to keep luminosity close to the maximum. Different tuning techniques have been applied to the CLIC BDS and in particular to the Final Focus System (FFS) in order to mitigate static and dynamic imperfections. Some of them require a fast luminosity measurement. Here we study the possibility to use beam-beam backgrounds processes at CLIC 3 TeV CM energy as fast luminosity signal. In particular the hadrons multiplicity in the detector region is investigated.Comment: Proceedings of LCWS1

    IMPERFECTION TOLERANCES FOR ON-LINE DISPERSION FREE STEERING IN THE MAIN LINAC OF CLIC

    Get PDF
    Abstract Long-term ground motion misaligns the elements of the main linac of CLIC over time. Especially the misaligned quadrupoles create dispersion and hence the beam quality is decreased gradually due to an effect called chromatic dilution. Over longer time periods, orbit feedback systems are not capable to fully recover the beam quality and have to be supplemented by dispersion correction algorithms. In this paper, such and dispersion correction algorithm is presented, which is an extended version of the well-known dispersion free steering algorithm. This extended algorithm can recover the beam quality over long time scaled without stopping the accelerator operation (on-line). Tolerances for different imperfections of the system have been identified and a strong sensitivity to the resolution of the wake field monitors of the main linac accelerating structures has been identified. This problem can be mitigated by using a local excitation scheme as will be shown in this work

    Pathogen dependent effects of high amounts of oxytocin on the bloodmilk barrier integrity during mastitis in dairy cows.

    Get PDF
    The reduction of antibiotic use in food producing animals becomes increasingly important. Therefore, suitable alternatives for mastitis treatment in dairy cows have to be considered. Oxytocin (OT) induces milk ejection and hence supports milk removal from infected mammary quarters. Beyond udder emptying, the injection of very high dosages of OT causes increased somatic cell counts (SCC) in milk and enables the transfer of immunoglobulins (Ig) from blood into milk through a reduced blood-milk barrier integrity. The aim of the present study was to investigate pathogen-specific changes of SCC, the blood derived milk components lactate dehydrogenase (LDH), serum albumin (SA), and IgG in milk of cows suffering from mastitis caused by different pathogens treated with two intravenous injections of high dosages of OT (100 IU). Milk samples from 184 dairy cows from different farms were collected on day 1 (day of clinical examination and mastitis diagnosis) and on days 2, 3, 14, and 28. Bacteriological examination (day 1) identified involved pathogens. Cows were randomly assigned to treatment (OT injections on days 1 and 2) or control group (no OT). Independently of the assigned experimental group, cows received the common therapy protocol of the veterinary practice after sample collection if the general condition was affected. Milk SCC, LDH, SA, and IgG changed specifically depending on involved pathogens. Highest values of all three parameters were measured in mastitis caused by Streptococcus uberis. Changes were less pronounced with other Streptococci spp., Staphylococci spp. or Corynebacterium bovis. Oxytocin treatment did not affect any of the studied parameters independent of the involved pathogen. Only in quarters infected with Staphylococci other than Staphylococcus aureus a decreased SCC and increased IgG concentrations in quarters, where no pathogens were detected, were observed. Thus, high dosage OT administration is obviously not suitable as a stand-alone mastitis treatment in dairy cows

    Interaction point feedback design and integrated simulations to stabilize the CLIC final focus

    Get PDF
    International audienceThe Compact Linear Collider (CLIC) accelerator has strong precision requirements on offset position between the beams. The beam which is sensitive to ground motion needs to be stabilized to unprecedented requirements. Different Beam Based Feedback (BBF) algorithms such as Orbit Feedback (OFB) and Beam-Beam Offset Feedback (BBOF) have been designed. This paper focuses on the BBOF control which could be added to the CLIC baseline. It has been tested for different ground motion models in the presence of noises or disturbances and uses digital linear control with or without an adaptive loop. The simulations demonstrate that it is possible to achieve the required performances and quantify the maximum allowed noise level. This amount of admitted noises and disturbances is given in terms of an equivalent disturbance on the position of the magnet that controls the beam offset. Due to the limited sampling frequency of the process, the control loop is in a very small bandwidth. The study shows that these disturbances have to be lowered by other means in the higher frequency range

    Experimental Verification Towards Feed-Forward Ground Motion Mitigation at ATF2

    No full text
    International audienceWithout counter measures, ground motion effects would deteriorate the performance of future linear colliders to an unacceptable level. An envisioned new ground motion mitigation method (based on feed-forward control) has the potential to improve the performance and to reduce the system cost compared to other proposed methods. For the experimental verification of this feed-forward scheme, a dedicated measurement setup has been installed at ATF2 at KEK. In this paper, the progress on this experimental verification is described. An important part of the feed-forward scheme could be already demonstrated, namely the prediction of the orbit jitter due to ground motion measurements

    Study of the Stabilization to the Nanometer Level of Mechanical Vibrations of the CLIC Main Beam

    Get PDF
    Original publication available at http://www.jacow.org/International audienceTo reach the design luminosity of CLIC, the movements of the quadrupoles should be limited to the nanometre level in order to limit the beam size and emittance growth. Below 1 Hz, the movements of the main beam quadrupoles will be corrected by a beambased feedback. But above 1 Hz, the quadrupoles should be mechanically stabilized. A collaboration effort is ongoing between several institutes to study the feasibility of the "nanostabilization" of the CLIC quadrupoles. The study described in this paper covers the characterization of independent measuring techniques including optical methods to detect nanometre sized displacements and analyze the vibrations. Actuators and feedback algorithms for sub-nanometre movements of magnets with a mass of more than 400 kg are being developed and tested. Input is given to the design of the quadrupole magnets, the supports and alignment system in order to limit the amplification of the vibration sources at resonant frequencies. A full scale mock-up integrating all these features is presently under design. Finally, a series of experiments in accelerator environments should demonstrate the feasibility of the nanometre stabilization

    The Compact Linear Collider (CLIC) - 2018 Summary Report

    Get PDF

    The Compact Linear Collider (CLIC) - 2018 Summary Report

    Get PDF
    The Compact Linear Collider (CLIC) is a TeV-scale high-luminosity linear e+ee^+e^- collider under development at CERN. Following the CLIC conceptual design published in 2012, this report provides an overview of the CLIC project, its current status, and future developments. It presents the CLIC physics potential and reports on design, technology, and implementation aspects of the accelerator and the detector. CLIC is foreseen to be built and operated in stages, at centre-of-mass energies of 380 GeV, 1.5 TeV and 3 TeV, respectively. CLIC uses a two-beam acceleration scheme, in which 12 GHz accelerating structures are powered via a high-current drive beam. For the first stage, an alternative with X-band klystron powering is also considered. CLIC accelerator optimisation, technical developments and system tests have resulted in an increased energy efficiency (power around 170 MW) for the 380 GeV stage, together with a reduced cost estimate at the level of 6 billion CHF. The detector concept has been refined using improved software tools. Significant progress has been made on detector technology developments for the tracking and calorimetry systems. A wide range of CLIC physics studies has been conducted, both through full detector simulations and parametric studies, together providing a broad overview of the CLIC physics potential. Each of the three energy stages adds cornerstones of the full CLIC physics programme, such as Higgs width and couplings, top-quark properties, Higgs self-coupling, direct searches, and many precision electroweak measurements. The interpretation of the combined results gives crucial and accurate insight into new physics, largely complementary to LHC and HL-LHC. The construction of the first CLIC energy stage could start by 2026. First beams would be available by 2035, marking the beginning of a broad CLIC physics programme spanning 25-30 years
    corecore